Unit Size |
160mm *106mm |
Unit Packing |
Standard |
Unit Packing Size |
21×13.8×137.5px |
Accessories |
User Manual, warranty card |
FUNCTION INTRODUCTION |
Conventional Function |
off-line operation; real time supervision; photo display; mass storage; flexible user privilege setup; remote unlocking; multi-user supervision; quick setting; convenient checking and query; revisable and printable report form; report form;report can be exported to excel file; card+password unlocking; alarm for long time unclosing ; alarm for invalid card swiping; first card unlocking;alarm for illegal break in; unlocking at definite time; e-map etc. |
Professional function |
for professional users such as bank,cash house, telecom station, power supply station,prison and police station: interface locking; intimidation alarm; integrated fire control;anti-pass-back and anti-tail; interlocking;multi-card unlocking; emergency double locking; in door population checking; unlocking based on internal and external validation. |
all-in-one-card management system |
normal shift and multi-shifts time attendance management system; fixed ration dining management system; meeting attendance management system; Online patrol management system and security alarm management system. |
PARAMETER |
Communication |
TCP/IP 10M/100M adaptive |
English Software supportable database: |
Access and SQL |
Description |
Control 1 door, get in and out door by swiping card, or get in by swiping card and get out door by button |
Power Supply |
12VDC 4-7A |
Power Consumption of Circuit Board |
Less than 100mA |
Input Format of Reader |
Wiegand 26 (All card reader with compatible protocol, such as Motorola , HID, EM , Mifare one etc) |
Quantity of Readers |
2pcs |
Door Controlled |
1 |
Door opening time extending setting |
1-600 seconds(adjustable) |
Max qty of controller |
No limit |
|
Remark: N denotes qty of computer serial Port or qty of 485hub port, support 256pcs ports |
Operation Temperature |
minus 40°C-70°C |
Operation Humidity |
10-90 % RH , No Condensation |
Qty of users |
20,000 Users |
Qty of Event Buffers(off-line) |
100,000 event buffers |
Power interruption protection measure |
High Speed Memory, Records never lose |
Max Distance from Reader to Controller |
100m (suggestion distance 80m) |
Max Distance between Controllers |
RS232: Communication Distance less than 13m, suggestion distance is 3m or less |
RS485: bus line max length 1200m, suggestion length 1000m or less, if expansion device added, the distance could be 3000m |
TCP/IP: Depends on net coverage area |
Collocations |
PCB board, case, power, power line, serial port communication line, software, manual, certificate, key(2pcs), carton |
Alarm for long time door open, illegal break in, intimidate |
Yes |
Open and close door at long time |
Yes |
Open door in remote distance |
Yes |
Inter block |
Yes |
Anti pass back and tail |
Yes |
Multi-card open door |
Yes |
Open long time at specified time |
Yes |
Electronic map |
Yes |
Urgency locking |
Yes |
First card unlocking |
Yes |
Unlock based on internal and external validation |
Yes |
Keypad (card+password, supper password) |
|
Remote Administration |
No |